1 x 2 teeth, longitudinal grooves, 7-1/2" (19.1 cm) ?Long Hysterectomy Forceps feature curved blades with longitudinal grooves to firmly grip the tough ligament on both sides of the uterus during the hysterectomy procedure. The blades feature 1X2 teeth for added grip. The ring handles feature a locking mechanism to hold the blades in various positions.
14-1/8" (36.0 cm)?Luikart-Simpson Obstetrical Forceps feature curved semifenestrated cephalic blades to grasp the fetal head and aid in the delivery process. The handle is grooved to provide the obstetrician with a comfortable grip on the instrument during use. The forceps can be articulated around the fetal head to provide a firm grip and traction.
long slender atraumatic jaws w/ longitudinal serrations, curvedM.D. Anderson Hysterectomy Clamps are commonly used in hysterectomy procedures. The long, slender atraumatic jaws with longitudinal serrations are ideal in hysterectomy for grasping adnexal tissue. The forceps are available in various lengths to accommodate a wide range of cases.
box lock, 10-1/4" (26.0 cm)?Maier Dressing Forceps are commonly used to dress wounds. The forceps feature ring handles and serrated hollow clamps at the tip. The forceps are available straight or curved with or without a catch to accommodate various cases.
graduated in centimeters & inches, 13-1/2" (34.0 cm)?Martin Pelvimeter is used in obstetrics and gynecology to assess the size of the female pelvis in relation to childbirth to determine whether natural vaginal delivery is possible. The pelvimeter features two bulbed arms to grasp the pelvis width and a ruler at the hinge graduated in centimeters and inches. Please note that…
2x3 atraumatic teeth, 1-5/8" (41.0 mm) jaw length, 8-1/2" (21.6 cm) ?Masterson-Type Hysterectomy Forceps feature atraumatic teeth to securely grasp the tough ligament on both sides of the uterus in hysterectomy procedures with minimal tissue trauma. The ring handles feature a lock mechanism to hold the blades in position. The forceps are available with straight or curved blades to accommodate…
2x3 atraumatic teeth, 1-3/4" (45.0 mm) jaw length, 10-1/2" (26.7 cm) ?Masterson-Type Pelvic Clamp is commonly used to stabilize the pelvis during and after hysterectomy procedures. The clamp features atraumatic teeth to minimize tissue injury. Available straight or curved to accommodate a wide range of cases.
serrated, 14.0 mm jaws, curved, 9-1/2" (24.0 cm)?McClintock Placenta Forceps are ideal for removal of the placenta after the mother has given birth. The serrated teeth on the curved jaws allow for a firm grasp on the placental tissue. The ring handles allow the obstetrician to operate the instrument comfortably and with ease.
15" (38.0 cm)?McLane-Luikart Obstetrical Forceps are commonly used in the delivery process. The rounded cephalic curve of the blades is designed to grasp the unmolded fetal head and provide traction for its migration through the birth canal. The grooved handle provides the obstetrician with a comfortable and secure grip of the instrument during its use.
14-1/4" (36.0 cm)?McLane-Tucker Obstetrical Forceps are designed to aid in the delivery process by firmly grasping the fetal head and providing traction. The blades feature a more rounded cephalic curve for the unmolded fetal head, commonly seen in multiparous women. The grooved handle provides a comfortable and secure grip for the obstetrician.
9-3/4" (24.5 cm) Measuring Probe Width Ruler is composed of premium grade German stainless steel for durability and easy sterilization. The instrument is protected by the Surgical manufacturer warranty on defects in materials and workmanship. Please note that website images are often representative of the product family and may not conform to the exact specifications or features of the item…
l Mikulicz Peritoneal Clamp Forceps are used in gynecological procedures in the pelvic cavity by separating the peritoneal tissue. The forceps feature ring handles with a lock mechanism and curved serrated blades. Available in different lengths to accommodate a wide range of cases.
set of 6, including handle, sizes 1.0 mm to 3.0 mm ?Mini Cervical Dilator Set features dilators of various width sizes for various cases. These dilators are designed for patients with a stenotic os. The rounded dilator tips prevent puncture of the uterine wall. The set is available with a universal handle that is able to hold all of the…
4" (10.0 cm)Miyazaki Notched Speculum features a perpendicular blade with a notch at the end for use in sacrospinous suspension ligatures. The instrument is available in German stainless steel for easy sterilization.
medium, short blades, 3-1/3" x 1-5/8" (8.5 cm x 4.0 c?Moore-Graves Speculum features dual blades perpendicular to the handle with a screw-lever mechanism to open and hold the blades in the vaginal canal. The instrument is ideal for observation and operation in the vaginal canal. Made of premium grade German stainless steel for easy sterilization.
w/ hinged shaft & sliding collar lock, 10" (25.0 cm) ?Murless Head Extractor is designed to aid in the delivery process by exposing the fetal head. The single-blade fenestrated instrument features a hinged shaft and a sliding collar lock to convert the extractor into a single rigid instrument in the appropriate position. The exaggerated cephalic curve is placed under the…
2x2 teeth, straight, 9-1/2" (24.0 cm)? Museux Vulsellum Forceps feature 2X2 serrated jaws to firmly grip the uterus during surgical procedures. The forceps are available with two different jaw widths to accommodate a range of cases. The ring handles allow for a comfortable and secure grip on the instrument.
10-1/4" (26.0 cm)?Newport Cervical Manipulator features a V-shaped hook at the end of a thin, cylindrical handle to aid the surgeon in a variety of diagnostic and surgical functions in the uterus including dilating, grasping, scraping, measuring, etc. It can also be used to hold the cervix or fundus for obstetric-gynecologic procedures. Please note that website images are often representative…
9-3/4" (24.8 cm)?Novak Endocervical Suction Biopsy Curette features an angled, serrated tip to aid in the removal and collection of biopsy tissue from the endocervix. The tip is at the end of a long, slender handle. The curette is available in various width sizes to accommodate a wide range of cases. Please note that website images are often representative of…
O'Sullivan-O'Connor Self Retaining Vaginal Speculum set is ideal for fixed retraction of the vaginal walls and access to the vaginal canal for inspection and/or surgery. The frame features two fixed lateral blades and screw mechanisms to fix three center blades to the frame and keep the vaginal canal open. The speculum is available with various sized center blades to accommodate…
85 degree angle, 3/8", 10-1/4" (26.0 cm)?Offset Hook features a hook angled 85 degrees from the handle and is commonly used in the removal of an intrauterine device from the uterus. The etched handle allows for a secure grip by the surgeon to prevent fingers from slipping. Made of premium grade German stainless steel. Please note that website images are…
hollow, fenestrated jaws, 9" (22.9 cm) ?Overstreet Endometrial Polyp Forceps are commonly used for the removal of polyps from the uterus. The forceps feature hollow clamps with fenestrated jaws to firmly grasp the polyp to be removed. The ring handles allow for comfortable and secure grip of the instrument.
Pederson Ebonized Vaginal Speculum is designed to aid in the visualization of the vaginal canal for diagnostic and/or procedural purposes. Ebonized instruments feature a durable, black coating for use in laser surgery procedures. The ebonized finish is designed to absorb stray energy and reduce reflection, thus reducing the risk of injury by laser. Most instruments, including ones not shown ebonized…
one smoke tube ?Pederson Nonconductive Speculum is designed to aid in the visualization of the vaginal canal for diagnostic and/or procedural purposes. Insulated instruments feature a smooth, durable, non-conductive nylon coating for LEEP, LLETZ and other electrosurgical ob-gyn procedures. The blue nylon resists abrasion and provides excellent insulation. These instruments are fully autoclavable, and can be insulated however needed, including…
Pederson Vaginal Speculum is a double-bladed instrument with a screw mechanism to keep the blades open once inserted into the vaginal canal. The speculum is designed to aid in the visualization of the vaginal canal for diagnostic and/or procedural purposes. The instrument is available in various sizes of blades to accommodate a wide range of cases.
8-1/4" (21.0 cm) ?Phaneuf Artery Forceps are designed to clamp down ruptured blood vessels. The forceps feature ring handles with a lock to hold the clamp in position. The serrated teeth grasp onto the blood vessels with minimal injury. Available in straight or curved blades to accommodate a wide range of cases.
17-1/2" (44.0 cm) ?Piper Obstetrical Forceps are commonly used to aid in the delivery process by grasping the fetal head with the fenestrated blades. The forceps feature a perineal curve to be used on the head in a breech delivery. Made of premium grade German stainless steel for durability and easy sterilization.
3.0 mm cup, 10" (25.0 cm)? ? ?Polyp Grasping Forceps are commonly used for removal of polyps from the uterus. The forceps feature a cup at the end of ring handles and a spring shaft to collect the polyps. The ring handles allow for a comfortable grip and controlled closing of the jaws.
Post-Hysterectomy Vaginal Speculum features a single curved blade at the end of an angled handle for insertion into the vaginal canal. The instrument is primarily used after a hysterectomy procedure for aid in visualization of the vaginal canal. It is available in various sizes to accommodate various cases.
10" (25.0 cm) ?Pozzi Tenaculum Forceps are commonly used in surgery to seize blood vessels or to steady the cervix and uterus. The sharp pointed hooks at the tips hold different parts during the surgery. They are controlled by ring handles for comfortable and controlled use.
double-ended, 11-1/2" (29.2 cm) l Pratt Uterine Dilator features double-ended rounded dilators to measure the level of dilation or facilitate further dilation of the uterus. The dilators are angled at the ends. The instrument is available in various width sizes to accommodate a wide range of cases. Please note that website images are often representative of the product family…
9-1/4" (23.5 cm)?Randall Endocervical Suction Biopsy Curette features an angled tip at the end of slender curette with a suction for scooping out biopsy tissue from the endocervix in the uterus. The curette is available in various width sizes to accommodate a wide range of cases. The instrument is made of premium grade German stainless steel for easy sterilization. Please…
rigid shaft, 12-1/2" (32.0 cm)?Recamier Placenta Curette is designed to remove the placenta from a woman's uterus after childbirth. The curette features a loop tip at the end of a thick cylindrical handle. It is available with a rigid shaft and sharp or blunt loop tips to accommodate various cases. Please note that website images are often representative of the…
3-1/2" x 4/5" (9.0 cm x 2.0 cm), 7" (17.8 cm)?Redundant Nonconductive Wall Retractor features ring handles with a lock mechanism and retractor blades at a right angle to the handle to aid the surgeon in opening the vaginal canal for better viewing and greater access for surgical procedures. Insulated instruments feature a smooth, durable, non-conductive nylon coating for LEEP,…
7" (18.0 cm)?Redundant Wall Retractor features ring handles with a lock mechanism and retractor blades at a right angle to the handle to aid the surgeon in opening the vaginal canal for better viewing and greater access for surgical procedures. The retractors are available in different blade sizes to accommodate various cases. Please note that website images are often representative…
8-1/4" (21.0 cm)? ?Reich Nechtow Hysterectomy Forceps are commonly used in hysterectomies to grasp the tough ligament on either side of the uterus. The blades feature diagonal grooves for improved grasping ability. The forceps are available straight or curved to accommodate a wide range of cases and anatomical variations.
2x3 atraumatic teeth, sarot-style shanks, 1-1/2" (38.0 mm) jaw length, 8-3/4" (22.0 cm)?Rogers-Type Hysterectomy Forceps are designed to clamp the tough ligament on both sides of the uterus in a hysterectomy procedure. The atraumatic teeth provide a firm grip with minimal tissue injury. The forceps are available with straight, curved, or angled blades to accommodate a wide range of cases.
Saenger Placenta & Ovum Forceps are ideal for procedures involving removal of the placenta or other products of conception from the uterus to prevent infection. The wide jaws allow the obstetrician to grasp large amounts of tissue at once. The forceps are available straight or curved with or without a ratchet locking mechanism to fit various preferences.
heavy, straight, sharp/blunt, 8-1/4" (21.0 cm)Schroeder Episiotomy Scissors are commonly used in episiotomy procedures to make the surgical incision in the perineum and posterior vaginal wall during labor to facilitate childbirth. The scissors feature heavy, straight blades with the ability to make sharp/blunt cuts. Please note that website images are often representative of the product family and may not conform…
10" (25.0 cm) shaft? Schroeder Nonconductive Tenaculum is used for cervical stabilization in gynecologic procedures. Insulated instruments feature a smooth, durable, non-conductive nylon coating for LEEP, LLETZ and other electrosurgical ob-gyn procedures. The blue nylon resists abrasion and provides excellent insulation. These instruments are fully autoclavable, and can be insulated however needed, including with exposure to the stainless steel in…